V676
®
/ V476
®
CONTROL CONSOLE USER MANUAL 109
General Operations
Operation of the Timing Filter and Function Filter can be done from the central touchscreen (available on the front
panel) or the Timing/Filter Display window (available from the Operation menu). The operations are basically identical
whether you are using the touchscreen or software window.
To select the mode:
To open the Timing Filter or Function Filter, press the appropriate button at the bottom of the touchscreen. Only one
mode is visible at a time, although in the case of the Function Filter, it does not have to be visible for selected filters to
affect console operation.
Note: If a store command is initiated while the touchscreen is in the Timing Filter, then the screen will automatically
switch to the Function Filter until the store operation is complete.
To s e t p a ram e ter s :
Select parameters by touching the appropriate location on the screen, and when necessary, enter values using the
command-line keypad.
Depending on the current function,
Time Filter Enter or Function Filter To Cue must be pressed before the settings
will be applied to store or playback operations.
Tem p lat e s:
The template section, found at the bottom of both the Timing Filter and Function Filter screens, provides 20
programmable templates that can be used to store frequently used settings.