DMX512 REFERENCE GUIDE 25
Mini AC Line Disconnect (30A)
CAUTION: Although the maximum operating limit is 30A, we recommend that continuous operating current
does not exceed 20A.
The mini (30A) AC line disconnect is a safety device containing a three-phase, 30A
circuit breaker serving as a master on/off switch for the system. It is similar to the
200A AC line disconnect, but is used primarily for smaller systems. The unit connects
to 30A service through a 10-foot, 8/5 pig tail. There are two types of cable
assemblies: receptacle connector to bare pigtails, and receptacle connector to plug
connector. The mini line disconnect connects to the mini-ACS rack with a 20- or 80-
foot, 8/5 cable assembly. One line disconnect is required for each 30A service.
CAUTION: The mini (30A) AC disconnect is not approved for use in Europe.
Figure 2-2: Mini AC Line Disconnect
INPUT
OUTPUT
Power
Indicator
Bare wire to Hubbell connector Hubbell to Epic connector
from house AC service to Mini-ACS Rack