TESTING AND TROUBLESHOOTING : TEST SOFTWARE
02.3004.0300.54 99
4
Test Software/Test Tables
The following tables contain test software test numbers, parameters, error codes, and comments. Use
these tables to run luminaire tests.
Note: Test numbers not listed are not valid.
CAUTION: Tests should not be run for more than 30 seconds, as this can further damage the
luminaire. Any tests run at FULL SPEED should not be run for more than 15 seconds.
Table 4-1: VL5 Family Mechanical Tests
Test Number Test Parameter Error Codes/Comments
000 Start Test 9 End Stop (Open)
001 Pan Test 8 End Stop (Clsd) 103 No Reset (Pan)
002 Tilt Test 7 Speed 1 (25%) 203 No Reset (Tilt)
004 Diffuser Test 6 Speed 2 (35%) 104 No Change (Pan)
005 Intensity Test
(VL5Arc Only)
5 Speed 3 (45%) 204 No Change (Tilt)
4 Speed 4 (55%)
006 Blue Filter Test 3 Speed 5 (65%)
007 Amber Filter Test 2 Speed 6 (75%)
008 Magenta Filter Test 1 Speed 7 (85%)
0 Speed 8 (Full Speed)
012 All Motors
(synchronized)
013 All Motors
(unsynchronized)
912 End Motor
(in calibration position)
Table 4-2: VL5 Family Default Programs
Test Number Test Functions
31 Pan and Tilt 701 Pan 25% Speed
702 Tilt 25% Speed
37 VL5 Functions 704 Edge 25% Speed
706 Blue Filter Test 25% Speed
707 Amber Filter Test 25% Speed
708 Magenta Filter Test 25% Speed