TESTING AND TROUBLESHOOTING : TEST SOFTWARE
02.3004.0300.54 115
4
Table 4-14: Program Mode Selection
Test Number Test Parameter Error Codes/Comments
30 Enter PGM Mode Parameters do not store with
tests.
Indicates test number for selection:
flashing for deselection, P if invalid
test number.
9 Synchronized Error code displays during test
31 Test Program 8 Unsynchronized
32 Test Program 7 Sequential Mode 5 min.
33 Test Program 6 Sequential Mode 2 min.
34 Test Program 5 Sequential Mode 1 min.
35 Test program 4 Sequential Mode 45 sec.
36 Test Program 3 Sequential Mode 30 sec.
37 Test Program 2 Sequential Mode 20 sec.
38 Test Program 1 Sequential Mode 10 sec
39 Test Program 0 Sequential Mode 5 sec.
Table 4-15: VLM Default Test Programs
Test Number Tests Functions
31 Pan and Tilt 701 Pan, 25% Speed
702 Tilt, 25% Speed
37 VL5 Functions 704 Edge, 25% Speed
706 Color 1, 25% Speed
707 Color 2, 25% speed
708 Color 3, 25% Speed
38 VLM Spin 703 CW Spin, 50% Speed
39 VL6 Functions 703 Beam, 25% Speed
704 Edge, 25% Speed
705 Intensity, 25% Speed
506 Color 1, Continuous Frame
507 Color 2, Continuous Frame
60 Packup Cue
61 Open/Bulb-Adjust Cue