AC Line Current / Power vs. Voltage
Note:
+ Tested while running all motors except Intensity/Iris/Frost functions to allow ballast to remain stable at 1400W
output to lamp.
Photometric Data
Refer to the charts on the following pages.
TEST VOLTS FREQ AMPS VA POWER PF
1 170 50Hz 10.27 1746 1735 0.998
2 180 50Hz 9.62 1732 1721 0.995
3 200 50Hz 8.56 1712 1713 0.994
4 200 60Hz 8.57 1714 1709 0.996
5 210 60Hz 8.16 1714 1707 0.997
6 220 50Hz 7.77 1709 1704 0.991
7 230 50Hz 7.47 1718 1708 0.998
8 240 50Hz 7.14 1714 1705 0.993
9 240 60Hz 7.16 1718 1702 0.996
10 250 50Hz 6.83 1708 1704 0.992
11 260 50Hz 6.62 1721 1701 0.989
12 270 50Hz 6.45 1742 1689 0.966