100 BAD BOY
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
added to the UVLO circuit. The voltage must be advanced by a considerable margin before the SMPS recovers (turns
on) from an UVLO condition, thus preventing cycling.
The Ballast is rated at 200V-240V and drops out due to UVLO at 165V and recovers at 185V.
The 24V LVS is rated 100V-240V and drops out at 75V and needs 85V to recover.
In the US, we use a 120V line cord to tech a light if we don't need to strike the lamp.