BAD BOY
®
SPOT LUMINAIRE FIELD SERVICE MANUAL 69
Replacing the 3A Fuse
The 3 Amp fuse is located on the Pan/Tilt Controller PCB.
Parts:
70.3769.0003.0 1 EA FUSE, 3AMP SLO-BLO
Tools:
Needle-nose pliers, small
WARNING: Remove power from luminaire before performing any maintenance procedures.
To replace the 3A Fuse:
Step 1. Remove power from luminaire and allow components to cool for at least 5 minutes.
Step 2. At Pan Yoke Leg, remove Yoke Leg Cover.
Step 3. At Pan/Tilt Controller PCB, use needle-nose pliers to carefully remove and replace 3A fuse.
Figure 3-33: Removing 3A Fuse
3A Fuse
Pan/Tilt Controller PCB
CAUTION:
Use anti-static precautions
when working with PC boards.